ALerTox Stick
1

Rapid tests for allergen detection in food, drinks, and surfaces for internal Quality Control.

AlerTox Sticks advantages:

  • Quick and Reliable
  • Results in 10 minutes
  • No Cross-Reactivity
  • High Sensitivity
2

AlerTox Sticks are a practical tool for the control of allergen content in raw materials, final products, and working surfaces.

Industrial application

  • Semi-quantification of allergens in food
  • Food quality control
  • Trace allergen contamination in food, liquid and surfaces
  • Implementation and fulfillment of HACCP, ISO 22000, BRC,and IFS complianc
3
4

NOTE: As with any qualitative or semiquantitative test, results should be periodically validated with a quantitative test performed in an outside laboratory

Insite Listeria

5

InSite Listeria screens for Listeria species. It is used on food contact surfaces, including processing equipment after cleaning to detect Listeria. The test is a self-contained swab device with selective growth medium that inhibits most non-Listeria microorganisms and provides nutrients to support Listeria growth so it can be measured easily and quickly.

Darkening of media to grey/black after 24-48 hours at 37°C indicates a presumptive positive result for Listeria spp.

InSite non-Listeria

6

New InSite Listeria reduces presumptive positives from non-Listeria that could survive and grow in previous InSite Listeria tests. A new study by Hygiena evaluated the new test’s ability to detect Listeria species as well as select against non-Listeria. Both devices demonstrated a presumptive positive color change for all Listeria species tested. This is consistent with AOAC-RI certification for InSite media and AOAC-RI certification of new InSite Listeri.

7
8
Autoclave

Autoclave small electric 50x

9

Sterilizer

240 Volt, 50/60 Hz

1650 watts/6.88 amps

Capacity - 25 Quarts (Liquid)

Overall Height - 16 3/4 inches

Bottom Height - 12 1/4 inches

Inside Diameter - 12 5/8 inches

Inner Container

Inside Depth - 8 1/2 inches

Inside Diameter - 11 1/8 inches

Circumference - 35 7/8 inches

Capacity - 14 1/2 Quarts

Made in the U.S.A.

1 Year Limited 

Manufacturer's

Warranty

Underwriters

Laboratories Listed

Autoclave large electric 75x

10

Sterilizer

240 Volt, 50/60 Hz

1650 watts/6.88 amps

Capacity - 41 1/2 Quarts (Liquid)

Overall Height - 19 inches

Bottom Height - 14 1/4 inches

Inside Diameter - 15 1/4 inches

Inner Container

Inside Depth - 10 1/4 inches

Inside Diameter - 14 inches

Circumference - 44 1/2 inches

Capacity - 27 Quarts

Made in the U.S.A.

1 Year Limited

Manufacturer's

Warranty

Underwriters

Laboratories Listed

Autoclave HVA 85/110

11
12
Centriuge

DM0506

13
  • Speed Range : 300-5000rpm,increment: 10rpm
  • Max. RCF : 2350xg, increment: 10g
  • Speed accuracy : ±20rpm
  • Rotor capacity : 6x15ml/10mL/7mL/1.5-5mL
  • Run Time : 30sec-99min,HD(continuous running)
  • Programs Memory : 2

D1008

14
  • Max. Speed : 7000rpm
  • Max. RCF : 2680×g
  • Rotor Capacity : 0.2/0.5/1.5/2.0mL×8; 0.2mL×16 PCR strips or 0.2mL×2 PCR 8 strips
  • Run Time : Continuous operation
  • Noise Level : ≤45dB

D2012plus

15
  • Max. Speed : 1500rpm), increment:100rpm
  • Max. RCF : 15100×g, increment: 100×g
  • Speed Accuracy : ±20rpm
  • Rotor Capacity : 0.2mL/ 0.5mL/1.5mL/2mL×12 
  • Run Time : 30sec 99min/Continuous
  • Noise level : ≤54dB

D1524R

16
  • Max. Speed : 15,000rpm (200-15,000rpm) in 100rpm increments.
  • Max. RCF : 21,380×g, step: 10×g
  • Capacity : 1.5/2mL×24, 0.5mL×36, PCR8×4, 5mL×12, 5mL×18.
  • Temperature setting : 20℃- 40℃
  • Timing : 30s-99 min; HOLD (continuous running)
  • Noise : ≤56dB

D3024

17
  • Max.Speed : 15000rpm(200-15000rpm),increment:10rp
  • Max. RCF : 21380×g,  increment:10×g
  • Speed Accuracy : ±20 rpm
  • Rotor Capacity 5mL×18, 5mL culture tubex12 0.2mL/0.5mL/1.5mL/ 2mL×24,0.5mL×36,PCR8×4
  • Run Time 30sec-99min/Continuous
  • Noise Level 64dB

DM1424

17
  • Speed Range : 200-14000rpm, increment: 10rpm
  • Max. RCF : 18620×g
  • Speed Accuracy : ±20 rpm
  • Rotor Capacity : 2 type
  • Run Time : 30sec-99min/ Continuous

DM0412

19
  • Speed Range : 300-4500 rpm,increment: 100rpm
  • Max. RCF : 2490×g
  • Speed accuracy : ±20rpm
  • Rotor type : A12-10P, A650P

DM0424

20
  • Speed range : 500-4000rpm increment: 100rpm
  • Max. RCF : 2500×g
  • Speed accuracy : ±100rpm
  • Rotor : Swing6×15ml, Swing4×50ml,Angle 24×15 ml, Angle 12×10ml/8×15ml
  • Run time : 1-99min, HOLD
  • Program Blood: 3200rpm,10min. Urine: 1800rpm,5min. Faecal: 1300rpm,10min.
  • Noise ≤62dB(A)

DM1224

21
  • Speed Range : 500-12000rpm, increment: 100rpm
  • Max. RCF : 13680×g
  • Speed Accuracy : ±100
  • Rotor Capacity : 1 type
  • Run Time : 10sec-99min/Continuous

DM0408

22
  • Speed range : 300-4000rpm, increment: 100rpm
  • Max. RCF : 1900×g
  • Speed accuracy : ±100rpm
  • Rotor : Angel 8×15ml (Default),Angel 10ml×12
  • Run time : 1-99min, HOLD
  • Noise : ≤60dB(A)

DM0636

23
  • Speed range : 300-6000rpm, increment:10rpm
  • Max. RCF : 4020xg
  • Speed accuracy : ±20rpm
  • Max. Capacity : 100mLx4
  • Run Time : 30sec 99mins/continuous
  • Program Memory : 9
20
DNA/RNA Extraction

SpeedMill PLUS

24
  • Homogenization time range 1 sec to 4:59 min, total 20-30 min for complete NA purification
  • Steps of adjusting time 1 sec
  • Pre-programmed protocols YES
  • User-defined protocols YES
  • Storable protocols 20
  • Number of cycles 1-99
  • Protocol steps 1-6
  • Dimensions (W × H × D) 154 × 275 × 257 mm
  • Weight 12 kg
  • Power consumption 150 W (max)
Heating Baths

HBR 4 control

25
  • Heat output : 1000 W
  • Heating temperature range room temp. : -200 °C
  • Set temperature resolution : ±1 K
  • Controller oscillation (3 l water / 90 °C) : ±1 K
  • Controller oscillation (3l Silicone oil / 50mPas / 150°C) : ±2 K
  • Filling volume max. : 4 l
  • Filling point min. : 20 mm
  • Adjustable safety circuit : 50 - 210 °C
  • Permissible ambient temperature max. : 40 °C
  • Permissible relative humidity : 80 %

HB eco

26
  • Heat output : 1400 W
  • Heating temperature range room temp. : - 99 °C
  • Set temperature resolution : ±1 K
  • Controller oscillation (3 l water / 90 °C) : ±1 K
  • Absolute deviation/mean (3l water / 90 °C) : ±2 K
  • Filling volume max. : 4 l
  • Filling point min. : 60 mm
  • Fixed safety circuit : 109 °C
  • Permissible ambient temperature : 5 -40 °C
  • Permissible relative humidity : 80 %

HB digital

27
  • Heat output : 1400 W
  • Heating temperature range room temp. : - 180 °C
  • Set temperature resolution : ±1 K
  • Controller oscillation (3 l water / 90 °C) : ±1 K
  • Absolute deviation/mean (3l water / 90°C) : ±2 K
  • Controller oscillation (3l Silicone oil / 50mPas / 150°C) : ±2 K
  • Absolute deviation/mean (3 l Silicone oil / 50mPas/ 150°C) : ±4 K
  • Filling volume max. : 4 l
  • Filling point min. : 60 mm
  • Fixed safety circuit : 190 °C
  • Adjustable safety circuit : 50 - 190 °C
  • Permissible ambient temperature : 5 -40 °C
  • Permissible relative humidity : 80 %
Hotplate & Magnetic Stirrer

MS7-H550-S

28
  • Motor rating input : 15W
  • Motor rating output : 1.5W
  • Heating output : 1000W
  • Stirring positions : 1
  • Max. stirring quantity, [H2O] : 10L
  • Max. magnetic bar[length] : 80mm
  • Speed range : 0-1500rpm
  • Heating temperature range : Room temp.-550°C, increment 5°C
  • Temperature control : accuracy±10°C
  • Overheating protection : 580°C
  • External temperature sensor : PT1000 (accuracy ±0.2)
  • "Hot" warning : 50°C
  • Permissible ambient temperature and humidity : 5-40°C, 80%RH

MS-H340-S4

29
  • Work plate dimension : Φ135mm(5inc) Motor rating input : 1.8W×4
  • Heating Power : 500W×4
  • Stirring positions : 4
  • Max. stirring quantity of single position (H2O) : 10L
  • Max. magnetic bar : 40mm
  • Speed range : 200-1500rpm
  • Control accuracy of sensor[rpm] : ±20
  • Temperature range : 25-340℃
  • Over temperature protection : 420°C
  • External temp. sensor : PT1000(Accuracy±0.2℃
  • Permissible ambient temperature : 5~40°C
  • Permissible relative humidity : 80%RH

MS7-S

30
  • Speed Range : 20-200rpm
  • Heating Temperature Range : Room temp. to 180℃
  • Control Accuracy : water: ±1℃ oil: ±3℃
  • Heating Power : 1010 W
  • Stroke Displacement : Manual 110mm + auxiliary100mm
  • Interval Time Setting Range : 1~999s
  • Heating Bath: 300x300x240mm
  • Permissible Ambient Temperature : 5~40 ℃
  • Permissible Relative Humidity : 80%RH
Liquid Handling

MicroPette Plus

31
32

MicroPette Plus

33
34

Levo Plus

35
PCR dan Support Equipment

Biometra TRIO

Biometra TRIO
  • Capacity 3 blocks independent @ 48-well, 6x 8-well strips
  • Max. heating rate * 5.0 °C/s
  • Max.cooling rate * 4.2 °C/s
  • Temperature uniformity : 55 °C ± 0.20 °C after 15 s
  • 70 °C ± 0.30 °C after 15 s
  • 95 oC + 0.60 °C after 15 s
  • Temperature range 3 °C to 99 °C
  • Control accuracy ± 0.1 °C

Biometra TAdvanced

Biometra TAdvanced
  • Quick Block exchange in less than 10s
  • Max. heating rate * 8.0 °C/s
  • Max.cooling rate * 5.5 °C/s
  • Avg. heating rate * 7.0 °C/s
  • Avg. cooling rate * 4.5 °C/s
  • Max./Min. gradient* 40 °C/0.1 °C
  • Temperature uniformity : 95 oC + 0.50 °C after 15 s
  • 70 °C ± 0.25 °C after 15 s
  • 55 °C ± 0.15 °C after 15 s
  • Gradient temperature range 4 °C to 99 °C
  • Temperature range 3 °C to 99 °C
  • Control accuracy ± 0.1 °C

HB120-S

Biometra TOne
  • Block Aluminum, special alloy
  • Max. heating rate 4.0 °C/s
  • Max. cooling rate 3.3 °C/s
  • Max./min. gradient2 20 °C/0.1 °C (for G series)
  • Gradient temperature range2 20 °C bis 99 °C (for G series)
  • Temperature uniformity at 55 °C ± 0.20 °C (after 15s)
  • Temperature range 3 °C to 99 °C
  • Control accuracy ± 0.1 °C
  • Lid temperature range 30 °C to 110 °C
Rotary Evaporator

RE200-Pro

RE200-pro
  • Temperature range : Room temp. ~180℃(both water and oil) 
  • Control Accuracy : Water: ±1℃Oil: ±3℃
  • Rotation Speed : 10~150rpm
  • Evaporation capacity : Max.4.0L/h (water vapor volume)
  • Ultimate vacuum : Less 2.6hpa
  • Sample flask : Round flask 20L
  • Receiving flask : Round flask 10L with drain valve
  • Condenser : Two-section vertical triple serpentine condenser,cooling surface 1.2m2
  • Heating bath size : φ450×240mm

RE100-Pro

RE100-pro
  • Speed Range : 20-280rpm
  • Heating Temperature Range : Room temp. to 180℃
  • Control Accuracy : water: ±1℃ oil: ±3℃
  • Heating Power : 1300W
  • Stroke Displacement : automatic 150mm
  • Time Setting Range : 1-999min
  • Permissible Ambient Temperature : 5-40℃
  • Permissible Relative Humidity : 80%RH

RE100-S

RE100-S
  • Speed Range : 20-200rpm
  • Heating Temperature Range : Room temp. to 180℃
  • Control Accuracy : water: ±1℃ oil: ±3℃
  • Heating Power : 1010 W
  • Stroke Displacement : Manual 110mm + auxiliary100mm
  • Interval Time Setting Range : 1~999s
  • Heating Bath: 300x300x240mm
  • Permissible Ambient Temperature : 5~40 ℃
  • Permissible Relative Humidity : 80%RH
Shaker

ROCKER 3D digital

  • Temperature range : Room temp. ~180℃(both water and oil) 
  • Control Accuracy : Water: ±1℃Oil: ±3℃
  • Rotation Speed : 10~150rpm
  • Evaporation capacity : Max.4.0L/h (water vapor volume)
  • Ultimate vacuum : Less 2.6hpa
  • Sample flask : Round flask 20L
  • Receiving flask : Round flask 10L with drain valve
  • Condenser : Two-section vertical triple serpentine condenser,cooling surface 1.2m2
  • Heating bath size : φ450×240mm

ROLLER 6 digital

  • Speed Range : 20-280rpm
  • Heating Temperature Range : Room temp. to 180℃
  • Control Accuracy : water: ±1℃ oil: ±3℃
  • Heating Power : 1300W
  • Stroke Displacement : automatic 150mm
  • Time Setting Range : 1-999min
  • Permissible Ambient Temperature : 5-40℃
  • Permissible Relative Humidity : 80%RH

Loopster digital

  • Speed Range : 20-200rpm
  • Heating Temperature Range : Room temp. to 180℃
  • Control Accuracy : water: ±1℃ oil: ±3℃
  • Heating Power : 1010 W
  • Stroke Displacement : Manual 110mm + auxiliary100mm
  • Interval Time Setting Range : 1~999s
  • Heating Bath: 300x300x240mm
  • Permissible Ambient Temperature : 5~40 ℃
  • Permissible Relative Humidity : 80%RH
Spectrophotometers

SP-V1100

SP-V110
  • Spectral Bandwidth : 2.0nm
  • Wavelength Range : 320-1100nm
  • Wavelength Accuracy : ±0.5nm
  • Wavelength Repeatability : ≤0.3nm
  • Photometric Range : -0.3-3.0A, 0-200%T
  • Photometric Accuracy : ±0.002A@0.5A,±0.004A@1.0A, ±0.3%T@100%T
  • Photometric Repeatability : ≤0.001A@0.5A,≤0.002A@1.0A, ≤0.15%T@100%T
  • Stability : ≤0.002A/h @500nm (after preheat 2 hours)
  • Stray Light : ≤0.05%T@360nm
  • Sample Compartment : 4-position,10mm

SP-V1000

SP-V100
  • Spectral Bandwidth : 4.0nm
  • Wavelength Range : 325-1000nm
  • Wavelength Accuracy : ±2nm
  • Wavelength Repeatability : ≤1nm
  • Photometric Range : -0.3-3.0A, 0-200%T
  • Photometric Accuracy : ±0.003A@0.5A,±0.006A@1.0A,±0.5%T@100%T
  • Photometric Repeatability : ≤0.0015A@0.5A, ≤0.003A@1.0A,≤0.25%T@100%T
  • Stability : ≤0.002A/h @500nm (after preheat 2 hours)
  • Stray Light : ≤0.2%T@360nm
  • Sample Compartment : 4-position,10mm

SP-UV1100

SP-UV110
  • Spectral Bandwidth : 2.0nm
  • Wavelength Range : 190-1100nm
  • Wavelength Accuracy : ±0.5nm
  • Wavelength Repeatability : ≤0.3nm
  • Photometric Range : -0.3-3.0A, 0-200%T
  • Photometric Accuracy : ±0.002A@0.5A, ±0.004A@1.0A,±0.3%T@100%T
  • Photometric Repeatability : ≤0.001A@0.5A, ≤0.002A@1.0A,≤0.15%T@100%T
  • Stability : ≤0.002A/h @500nm(after preheat 2 hours)
Thermo Controls

HB105-S1

42
  • Temperature range[°C] : Room temp +5~105
  • Temperature setting range [°C] : 25~105
  • Temperature control accuracy[°C : 25~90:±0.3 dan 90~150:±0.6
  • Uniformity@37℃ [°C] : ±0.2
  • Operating temperature[°C] : +10~40
  • Operating humidity [% RH] : <80

HCM100-Pro

43
  • Temperature range : Heating: room temp. - 100°C Cooling: room temp. - below room temp. 15°C
  • Temperature setting range : 0.1-100℃
  • Temperature control accuracy: ± 0.5°C
  • Temperature uniformity : Max.± 0.5°C
  • Max. heating rate : 5.5°C/min
  • Max. cooling rate : 5°C /min(100°C room temp.), 0.5°C/min(below room temp.)
  • Mixing frequency : 200-1500rpm
  • Mixing orbit : 3mm
  • Overheating protection : 150°C

HB120-S

44
  • Temperature range : Room temp.-120°C
  • Temperature control accuracy[at 37℃] : ± 0.5°C
  • Temperature uniformity : ± 0.5°C
  • Max. heating rate : 5.5°C/min
  • Timer : 1min-99h59min
  • Overheating protection : 140°C
Vacuum

VACSTAR digital (Pump)

47
  • Pump rate max. (50/60Hz) : 1.32 m³/h
  • Pump rate max. (50/60Hz) : 22 l/min
  • Final pressure without gas ballast : 2 mbar
  • Input pressure : 2 - 1030 mbar
  • Speed range : 285 - 1200 rpm
  • Noise at low. Pressure : 54 dB(A)

MVP 10 basic vacuum pump

45
  • Pump rate max. (50/60Hz) : 1.7 m³/h
  • Pump rate max. (50/60Hz) : 28.3 l/min
  • Final pressure without gas ballast : 7 mbar
  • Input pressure : 7 - 1050 mbar
  • Speed (50Hz) : 1380 rpm
  • Speed (60Hz) : 1680 rpm
  • Noise at low. Pressure : 65 dB(A)
  • Overheating protection : 150°C

VC 10 lite Controller

46
  • Input pressure : 1 - 1050 mbar
  • Pressure max. for pressure sensor : 1.6 bar
  • Measurement range (absolute) : 1 -1100 mbar
  • Control range : 1 - 1100 mbar
  • Measurement uncertaint : 1 mbar
  • Medium temperature (gas) : 5 - 40 °C
  • Time setting min. : 1 s
  • Time setting max. : 6000 min
Viscometers

ROTAVISC SBS me-vi

48
  • Viscosity Measuring Range : 40000000 mPas
  • Viscosity Accuracy (FSR) : 1 %
  • Viscosity Repeatibility (FSR) : 0.2 %
  • Spring torque : 0.7187 mNm
  • Speed range : 0.01 - 200 rpm
  • Setting accuracy speed : ±0.01 rpm
  • Time setting range : 0.017 - 6000 min
  • Basic container volume : 600 ml

ROTAVISC SBS me-vi HELI

49
  • Viscosity Measuring Range : 40000000 mPas
  • Viscosity Accuracy (FSR) : 1 %
  • Viscosity Repeatibility (FSR) : 0.2 %
  • Spring torque : 0.7187 mNm
  • Speed range : 0.01 - 200 rpm
  • Setting accuracy speed : ±0.01 rpm
  • Time setting range : 0.017 - 6000 min

ROTAVISC lo-vi

50
  • Viscosity Measuring Range : 6000000 mPas
  • Viscosity Accuracy (FSR) : 1 %
  • Viscosity Repeatibility (FSR) : 0.2 %
  • Spring torque : 0.0673 mNm
  • Speed range : 0.01 - 200 rpm
  • Setting accuracy speed : ±0.01 rpm
  • Time setting range : 0.017 - 6000 min
Vortex Mixer

Hula Dancer digital

51
  • Diameter shaker : 4.5 mm
  • Berat pengguncnag yang diizinkan ( termasuk kelengkapan) : 0.1 kg
  • Motor rating input : 9.5 W
  • Motor rating output : 5 W
  • Kecepan minimal ( dapat disesuaikan) : 1200 rpm
  • Kecepatan maksimal : 2800 rpm
  • Temperatur lingkungan yang dizinkan : 5 - 40 °C
  • Kelembapan relatif yang diizinkan : 80 %

MS 3 digital

52
  • Diameter shaker : 4.5 mm
  • Berat pengguncnag yang diizinkan ( termasuk kelengkapan) : 0.5 kg
  • Motor rating input : 10 W
  • Motor rating output : 8 W
  • Kecepan minimal ( dapat disesuaikan) : 200 rpm
  • Range kecepatan : 0 - 3000 rpm
  • Pengaturan waktu minimal : 1 s
  • Rentang Pengaturan waktu : 1 - 999 min
  • Temperatur lingkungan yang dizinkan : 5 - 40 °C
  • Kelembapan relatif yang diizinkan : 80 %

Vortex 2

53
  • Diameter shaker : 4 mm
  • Berat pengguncnag yang diizinkan ( termasuk kelengkapan) : 0.4 kg
  • Motor rating input : 39 W
  • Motor rating output: 9 W
  • Kecepatan minimal ( dapat disesuaikan) : 500 rpm
  • Kecepatan maksimal : 2500 rpm
  • Pengatur kecepatan skala : 0-6 Temperatur lingkungan yang dizinkan : 5 - 40 °C
  • Kelembapan relatif yang diizinkan : 80 %